FastRack: String Inverter Mount
Sollega Inverter Mount Attached Mount Detail Stamped
Stamped engineering detail for the mechanically attached configuration of the Sollega String Inverter Mount, showing the ballasted FR510 base anchored to the roof deck with mechanical roof anchors, the rail-to-L-bracket connection, and single, two, and three-inverter assembly layouts.
Sollega String Inverter Mount — Attached Mount Detail
Stamped detail drawing for the mechanically attached configuration, combining the FR510 ballast base with mechanical roof anchors into the deck. Includes side and front assembly views, the rail-to-L-bracket connection, and the anchor/deck connection detail.
Ballasted Inverter Mount — Side
- Components: string inverter, aluminum rail, Sollega FR510 base, mechanical anchor
- U-Anchor 2400 mechanical attachment
- Center of mass (C.O.M.) of inverter shall be placed directly over the U-Anchor 2400 mechanical attachment
Rail / L-Bracket Connection
- Aluminum L-brackets connect the inverter to the aluminum rail
- Stainless steel 5/16" T-bolt and serrated flange nut
Anchor / Deck Connection
- U-Anchor 2400 mechanical roof attachment / anchor
- Adhered to roof per manufacturer's recommendation, over existing roof membrane
- (4) #12 full-threaded wood screws, embedded minimum 1/4" past plywood deck
- Minimum 1/2" plywood deck
Assembly Configurations
- Full 3-inverter assembly (front)
- Full 2-inverter assembly (front)
- Full single-inverter assembly (front)